PRODUCT DETAILS

SPUN


TECHNICAL SPECIFICATIONS

PERSPECTIVE VIEW

PLAN VIEW

SIDE ELEVATION


DOWNLOADS


MATERIALS

FIRE FEATURE SHELL
High-performance glass fiber reinforced concrete.

BURNER SYSTEM
Stainless steel and or brass components

INFILL
Volcanic stone


PRECAST COLORS

CHARCOAL

CLAY

GULL

INKWELL

IVORY

LIMESTONE

SAND

TAUPE

PEWTER

MILLSTONE


BURNER SYSTEM COMPONENTS

16-gauge stainless burner pan

ANSI-approved stainless steel flex lines

Integrated CSA-certified log lighter valve

Burner (stainless steel or Warming Trends)

Natural gas or propane fittings

Powder-coated valve key


PLUMBING SECTIONALS

Reference technical drawings for typical clearances and suggested supply pressures.

HARD PIPE CONNECTION

FLEX HOSE CONNECTION


ELECTRONIC IGNITION SECTIONAL

TYPICAL LINEAR


SHIPPING INFORMATION & UNCRATING WORKFLOW

SPUN 36
Crated dimensions - 39" x 39" x 23"
Shipped weight - 460 lbs

SPUN 42
Crated dimensions - 45" x 45" x 23"
Shipped weight - 575 lbs

SPUN 48
Crated dimensions - 51" x 51 "x 23"
Shipped weight - 690 lbs

SPUN 52
Crated dimensions - 56" x 56" x 23"
Shipped weight - 800 lbs


FIRE FEATURE CARE AND MAINTENANCE

SUMMARY
Regular maintenance and safety checks of your fire feature are crucial. By adhering to proper care routines, you can prolong the lifespan of both the product and its individual parts. 

CONCRETE SHELL
Your LUMACAST product has been sealed to resist staining, scratching, and heat caused by reasonable wear and tear encountered during regular use in an indoor or outdoor environment. Please use caution to wipe up spills in a timely fashion, especially with highly acidic beverages. Avoid cutting or chopping food on your concrete surface, as it may abrade the sealer and most likely dull your cutlery. 

Observing a hairline crack on the finish of your fire feature shouldn’t cause concern; it’s a typical trait of concrete and doesn’t indicate a defect. The internal concrete benefits from glass fiber reinforcement, ensuring such cracks don’t expand further.

Lumacast recommends cleaning your concrete with mild, non-abrasive all-purpose household cleaners such as “Method” or “Seventh Generation” Spray-Cleaner. We also recommend “Pledge Specialty Surface Cleaner” as an all-in-one cleaner and protector. Please do not use harsh chemicals, as they may damage the sealer. Periodic cleaning with mild cleaning products is suggested to maintain the smooth look and finish of the concrete. 

TABLETOPS
Lumacast recommends cleaning your aluminum or wood-faced composite tabletop with mild, non-abrasive all-purpose household cleaners such as “Method” or “Seventh Generation” Spray-Cleaner. We also recommend “Pledge Specialty Surface Cleaner” as an all-in-one cleaner and protector. Please do not use harsh chemicals, as they may damage the powercoat on the aluminum and the epoxy on the composite tabletops. Periodic cleaning with mild cleaning products is suggested to maintain the smooth look and finish of the tabletops. 


BURNER SYSTEM CARE AND MAINTENANCE

NATURAL GAS & PROPANE BURNER ASSEMBLY
Annually inspect and clean the burner. If you detect any signs of damage, replace the burner assembly before using the appliance. Ensure that the replacement parts meet the standards of the set forth by Lumacast. Keep in mind that stainless steel will rust or corrode over time if contamination or debris is not cleaned or removed. To examine and clean the burner pan and ring, proceed with the following instructions: 

  1. Remove the infill media and examine the burner. Vacuum and clean it as necessary.

  2. Inspect the burner and burner assembly for warping and corrosion. Repair or replace components as necessary

  3. Verify that the holes on a stainless burner or the nozzles on Warming Trends burner are not clogged with debris. Clear as necessary.

  4. Clean the burner and burner assembly with a soft wire brush.

  5. On stainless burner assemblies, verify that the air mixer is clear of spider webs, insects and debris (the air mixer is located on the underside of the burner assembly).

  6. Verify that the stainless steel flex lines are tight and undamaged. Tighten and/or replace as necessary.

  7. Perform a leak test.